Products
Home Products Spare Parts Consulting Worker Safety Contact us

Current Transformer

 
Our products:
  • current transformers with 25 up to several hundred ampere primary current (output 0-20 ma or 0-10 volt dc)

  • monitoring systems

  • electronic control unit

type 313   25 - 100 A
type 513   100 - 500 A

 

A typical application of current transformers is the current control of heater bands or heating groups at extrusion systems, injection moulding machines or other machines where heating is an important parameter for product quality.

In case of a breakdown of the Solid-State-Relays, fuse or heater band failure, the control system (SPL) will detect the defect and will send an error message. In addition comfortable controllers are able to switch off the machine or single functions using a special program.

No external energy supply is needed for current transformers; transformers can be used with overstress

A possible breakdown of the heating system may lead to temperature fluctuations between setup and actual data.

 

 

structural shape B B1 H L Ø
Ewand 2.X 313 * 30 mm 44 mm 83 mm 64 mm 28 mm
Ewand 3.x 513 ** 30 mm 44 mm 110 mm 85 mm 45 mm
Assembly:
*  top hat rail 35 mm
** back panel

technical data:

type structural shape output M0 *3 M1 *4
Ewand 2.0 313 10 v dc    
Ewand 2.1 313 20 ma dc    
Ewand 3.0 513 10 v dc    
Ewand 3.1 513 20 ma dc    
P = 0,2 W; l = 0,02 A; lth. = 32 kA (1,0 s)
primary current. 25A, 40A, 50A, 75A, 100A, 200A please state in your order..
other primary currents on request.
*3, output voltage with minimal residual ripple (standard type), especially for exact measurement
*4, output, residual ripple, especially for multiplexcontrol and threephase applications

 

The electronic board is integrated in the current transformer. Primary wiring leads through a hole in the transformer (please check hole diameter).

For measuring small currents, wind the wire several times through the hole.

 

The current transformer is connected to the measuring instrument by binders  (+) and (-).
Single measurements and multiplexing is possible (please ask for further information).

Current transformers are suitable for monophase or threephase current.

 

 

Possible Application: